Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 8 Next »

Issue

After starting the configuration the corresponding tabs in the actions window are not shown or the content is not correct.

Solution

The corresponding cache database is damaged. In this situation deleting the related database cache on your system will force ECU-TEST to create a new database cache.

  1. Navigate to C:\Users\<your user name>\AppData\Roaming\TraceTronic\ and open the subfolder of your respective ECU-TEST version.
  2. Find the database cache file that is related to the missing/outdated tab in ECU-TEST (see table below) and delete it.
  3. Restart your configuration in ECU-TEST.
tabcache file
measurement accessdata_cache_a2l.sdb
calibration accessdata_cache_a2l.sdb
model access

data_cache_model*.sdb

ECU-TEST creates one such file for each model previously used.

When in doubt, delete all of them.

bus accessdata_cache_bus.sdb
diagnosis accessdata_cache_diag.sdb
service accessdata_cache_service.sdb

For example: If the bus tab is missing, delete the file "data_cache_bus.sdb".

  • No labels