Issue

I want to switch the CANoe version that ECU-TEST is using, but I am not able to modify it
in the test bench configuration (tbc). How can I change that?


Solution

A switch between CANoe versions in ECU-TEST is not possible. We get the information about the last
installed CANoe version from the Windows Registry.

This property only shows the versions which are used by ECU-TEST.
If you want to change the version, you have to reinstall/register the wanted CANoe version.

To re-register your CANoe search for the document AN-AND-1-117_CANalyzer_CANoe_as_a_COM_server.pdf.
which is located in installation directory (e.g. C:\Program Files\Vector CANoe 15\Doc).
Please take a look at chapter 1.4 COM Server Registration and follow the instructions for
Application Note: CANoe/CANalyzer as a COM Server.

  • No labels