Issue

After starting the configuration the corresponding tabs in the actions window are not shown or the content is not correct.

...

After starting the configuration the corresponding tabs in the actions window are not shown or the content is not correct.

Solution

The corresponding cache database is damaged. In this situation deleting the related database cache on your system will force

...

ecu.test to create a new database cache.

  1. Navigate to C:\Users\<your user name>\AppData\Roaming\TraceTronic\ and open the subfolder of your respective

...

  1. ecu.test version.

  2. Find the database cache file that is related to the missing/outdated tab in

...

  1. ecu.test (see table below) and delete it.

  2. Restart your configuration in

...

  1. ecu.test.

tab

cache file

measurement access

data_cache_a2l.sdb

calibration access

data_cache_a2l.sdb

model access

data_cache_model*.sdb

ECU-TEST

ecu.test creates one such file for each model previously used.

When in doubt, delete all of them.

bus access

data_cache_bus.sdb

diagnosis access

data_cache_diag.sdb

service access

data_cache_service.sdb

For example: If the bus tab is missing, delete the file

...

data_cache_bus.sdb

...

.