Page Properties | ||
---|---|---|
|
Issue
After starting the configuration the corresponding tabs in the actions window are not shown or the content is not correct.
...
- Navigate to
C:\Users\<your user name>\AppData\Roaming\TraceTronic\
and open the subfolder of your respective ECU-TEST version. - Find the database cache file that is related to the missing/outdated tab in ECU-TEST (see table below) and delete it.
- Restart your configuration in ECU-TEST.
tab | cache file |
---|---|
measurement access | data_cache_a2l.sdb |
calibration access | data_cache_a2l.sdb |
model access |
ECU-TEST creates one such file for each model previously used. When in doubt, delete all of them. |
bus access | data_cache_bus.sdb |
diagnosis access | data_cache_diag.sdb |
service access | data_cache_service.sdb |
For example: If the bus tab is missing, delete the file "data_cache_bus.sdb".