While trying to start the TBC I am running into a timeout error after 10 minutes.

Section
Column
width2%
Code Block
languagepy
themeConfluence
ToolLib time: 11:17:16.695 ControlDeskNGLib: Starting Online Calibration in ControlDesk ...
tts.core.toolingFramework.interface.Proxy.__call__: Timeout: Tool call aborted
tts.core.dataViewer.DataManager.UpdateModelObject: Port MDL01 (@local): PortExecuteJob() failed: Timeout: Tool call aborted



Is there a way to increase the time to make sure my tools can be loaded properly?

...

The timeout can be adjusted in the TBC file. This is a property of the tool host of the test bench configuration.


...


Warning

Keep in mind:

Increasing the tool timeout affects all tools of the tool host as well.
This might help you for loading a complex model structure, because ECU-TEST caches the initial
loaded information to speed up upcoming tool calls.